| Number of indoor units | – | 2–3 | pcs |
| Capacity | Cooling / Heating | 7,1 (2,3–8,5) / 8,6 (3,7–8,8) | kW |
| Power Supply | Into Outdoor Unit | 220 – 240 / 1 / 50 | V / Ph / Hz |
| Power Input | Cooling / Heating | 1,9 / 2,2 | kW |
| Rated Power Input | Cooling / Heating | 3,4 | kW |
| Power Current | Cooling / Heating | 8,4 / 9,9 | A |
| Rated Power Current | Cooling / Heating | 14,6 | A |
| SEER | – | 7,10 | – |
| SCOP | SCOP | 4,3 | |
| Energy Class | Cooling / Heating | A++ / A+ | – |
| Air Flow | Outdoor Unit | 3800 | m3 / h |
| Sound Pressure Level at 1 m | Outdoor Unit | 58 | dB(A) |
| Sound Power Level | Outdoor unit | 68 | dB(A) |
| Refrigerant / Charge / Eq. CO2 | – | R32 / 1,70 / 1,18 | type / kg / t |
| Additional Refrigerant | – | 20 | g / m |
| Refrigerant Liquid Pipe | Diameter | 3 x 6,0 | inch / mm |
| Refrigerant Gas Pipe | Diameter | 3 x 9,5 | inch / mm |
| Max pipe length without additional refrigerant | – | 30 | m |
| Maximum pipe length per indoor unit | – | 20 | m |
| Maximum overall length of piping | – | 60 | m |
| Max. Elevation | – | 15 | m |
| Dimension (w x h x d) | Outdoor Unit | 964 × 660 × 402 | mm |
| Package (w x h x d) | Outdoor Unit | 1032 × 737 × 456 | mm |
| Net / Gross Weight | Outdoor Unit | 47,5 / 52,0 | kg |
| Operating Temperature Range | Cooling | -15 ~ 43 | °C |
| Operating Temperature Range | Heating | – 22 ~ 24 | °C |
| Notes | The technical specification of the products may differ from the stated values according to product development by the manufacturer. Please refer to the parameters on the unit nameplate. | ||