| Capacity | Cooling / Heating | 16,0 (4,8-17,0) / 17,0 (4,5-18,0) | kW |
| Power Supply | Into Outdoor Unit | 380–415 / 3 / 50/60 | V / Ph / Hz |
| Power Input | Cooling / Heating | 5,40 / 5,70 | kW |
| Rated Power Input | Cooling / Heating | 6,80 | kW |
| Power Current | Cooling / Heating | 9,2 / 9,7 | A |
| Rated Power Current | Cooling / Heating | 12,0 | A |
| Air Flow | Outdoor Unit | 5500 | m3 / h |
| Sound Pressure Level at 1 m | Outdoor Unit | 60 | dB(A) |
| Sound Power Level | Outdoor unit | 75 | dB(A) |
| Refrigerant / Charge / Eq. CO2 | – | R32 / 3,50 / 2,36 | type / kg / t |
| Additional Refrigerant | – | 35 | g / m |
| Refrigerant Liquid Pipe | Diameter | 3/8 / 9,5 | inch / mm |
| Refrigerant Gas Pipe | Diameter | 5/8 / 15,9 | inch / mm |
| Max pipe length without additional refrigerant | – | 7,5 | m |
| Maximum overall length of piping | – | 75 | m |
| Max. Elevation | – | 30 | m |
| Dimension (w x h x d) | Outdoor Unit | 990 × 960 × 370 | mm |
| Package (w x h x d) | Outdoor Unit | 1153 × 1110 × 478 | mm |
| Net / Gross Weight | Outdoor Unit | 94,0 / 103,0 | kg |
| Operating Temperature Range | Cooling | – 20 ~ 52 | °C |
| Operating Temperature Range | Heating | – 20 ~ 24 | °C |
| Notes | The specification of products is subject to change based on further development of the units by the producer and can be changed without prior notice. Refer to rating label. | ||