Service and technical support for our clients:

ASGE-12BI

  • Cooling capacity 3,5 kW
  • Heating capacity 4,0 kW
  • 3-year warranty
  • DC Inverter technology
  • Autorestart function
  • Anticorrosion treatment of exchangers
  • SCMI-01.4 slave unit (control by 0–10 V)
  • SCMI-01.4 communication module is separate product
CapacityCooling / Heating3,5 / 4kW
Power SupplyInto Outdoor Unit220 – 240 / 1 / 50V / Ph / Hz
Power InputCooling / Heating0,95 / 1,05kW
Rated Power InputCooling / Heating1,35kW
Power CurrentCooling / Heating4,2 / 4,7A
Rated Power CurrentCooling / Heating6,0A
Air FlowOutdoor Unit3000m3 / h
Sound Pressure Level at 1 mOutdoor Unit50dB(A)
Sound Power LevelOutdoor unit64dB(A)
Refrigerant / Charge / Eq. CO2R32 / 0,78 / 0,53type / kg / t
Additional Refrigerant16g / m
Refrigerant Liquid PipeDiameter1/4 / 6,4inch / mm
Refrigerant Gas PipeDiameter3/8 / 9,5inch / mm
Max pipe length without additional refrigerant5m
Maximum overall length of piping3 / 30m
Max. Elevation15m
Dimension (w x h x d)Outdoor Unit818 × 596 × 378mm
Package (w x h x d)Outdoor Unit948 x 645 x 420mm
Net / Gross WeightOutdoor Unit37,0 / 40,0kg
Operating Temperature RangeCooling– 20 ~ 48°C
Operating Temperature RangeHeating– 20 ~ 24°C
 
Notes

The specification of products is subject to change based on further development of the units by the producer and can be changed without prior notice. Refer to rating label.
R32 (single component refrigerant HFC), GWP of refrigerant used: 675.
Contains fluorinated greenhouse gases covered by the Kyoto Protocol.

COMMUNICATION MODULE SCMI-01.4

Question about the Product